Configuration

All configuration options for sbam. Options are resolved with the following precedence: CLI flag > environment variable > config.yaml > built-in default.

Where CLI and HA add-on forms differ (different defaults, different validation, or different availability), the difference is noted inline.


Core API

Option Description CLI flag Env var HA add-on key Default
url Solcast forecast site URL. Multiple URLs supported (max 2), comma-separated. --url URL url —
apikey Solcast API key. --apikey APIKEY apikey —

Inverter Connection

Option Description CLI flag Env var HA add-on key Default
fronius_ip Fronius inverter LAN IP address. --fronius_ip FRONIUS_IP fronius_ip —
sunspec_type Must match the inverter's Modbus SunSpec Model Type. int_sf — the inverter is set to int + SF; sbam uses the fixed storage register addresses, as in previous versions. float — the inverter is set to float; sbam locates the SunSpec storage model (124) at runtime and writes nothing if it cannot find it, or if the model is shorter than the SunSpec definition or its InOutWRte_SF is not -2 (sbam writes charge/discharge rates as percentages with two decimals). auto — sbam locates the storage model the same way, which works with either inverter setting, and falls back to the int + SF addresses on devices without a SunSpec map. At startup, schedule reads the inverter's model type (read-only) and logs a warning if it does not match. Optimize mode writes to the same located registers. --sunspec_type SUNSPEC_TYPE sunspec_type int_sf

Charge Windows

Legacy single window

These options define a single charge window. When windows is configured, start_hr, end_hr, and max_charge will be ignored.

Option Description CLI flag Env var HA add-on key Default
start_hr Start time of the advantageous grid rate (HH:MM). Cross-midnight ranges supported. --start_hr START_HR start_hr 00:00
end_hr End time of the advantageous grid rate (HH:MM). Cross-midnight ranges supported. --end_hr END_HR end_hr 06:00
max_charge Maximum grid charging power in watts. --max_charge MAX_CHARGE max_charge 3500

Multi-window

The windows option replaces the single start_hr/end_hr/max_charge triple with an ordered list of charge windows. List order defines the daily sequence: the first entry starts first, the last entry ends last. Cross-midnight windows are supported.

Option Description CLI flag Env var HA add-on key Default
windows Ordered list of charge windows in YAML format. --windows WINDOWS windows []

Each window accepts these fields:

Field Required Description
name No Human-readable label shown in MQTT and logs. Auto-generated if empty.
start Yes Window start time (HH:MM).
end Yes Window end time (HH:MM). Cross-midnight supported.
max_charge Yes Maximum grid charging power in watts for this window.
forecast_horizon No Per-window forecast horizon override. See Forecast horizon modes.
consumption_horizon No Per-window consumption horizon override. See Consumption horizon modes.
tick_minutes No Evaluation interval in minutes within this window.
set_defaults No Whether to reset inverter to defaults when this window ends.
before_end_defaults_minutes No Minutes before window end to trigger defaults. 0 resets exactly at the window end. Whatever the value, the tick that leaves the window resets too, and ticks outside every window restore normal mode if the inverter is still held or force-charging, unless that came from a command given outside a window.
weekdays No Day-of-week filter for the window. See Weekday Filtering.
hold_battery No When true, block battery discharge while the window is active and sbam is not force-charging. Loads run from the grid at the window's price and the stored energy is kept for the expensive hours. PV can still charge the battery. sbam releases the hold when the window ends: with set_defaults, at its usual time; without it, at the window end. Default false.
reserve_horizon No until_solar sizes the battery reserve for this window from the forecast. See Reserve until solar. Empty keeps the static pw_batt_reserve.

Battery Reserve

The battery reserve defines a minimum charge level to maintain during the reserve window. The scheduler will not discharge below this threshold.

Option Description CLI flag Env var HA add-on key Default
pw_batt_reserve Minimum battery capacity to maintain in watt-hours. --pw_batt_reserve PW_BATT_RESERVE pw_batt_reserve 4000
batt_reserve_start_hr Start time for reserve window (HH:MM). Empty uses start_hr. --batt_reserve_start_hr BATT_RESERVE_START_HR batt_reserve_start_hr start_hr value
batt_reserve_end_hr End time for reserve window (HH:MM). Empty uses end_hr. --batt_reserve_end_hr BATT_RESERVE_END_HR batt_reserve_end_hr end_hr value
batt_min_soc Minimum state of charge (%) the battery keeps, as set in the inverter's battery settings (Fronius default 5 %). Set it to the same value: sbam neither reads nor writes the inverter's setting. Used by reserve_horizon: until_solar to size the reserve target, so a mismatch only mis-sizes that target and reserve_at_risk. --batt_min_soc BATT_MIN_SOC batt_min_soc 5
grid_import_limit Maximum grid import in watts for the whole site (usually the contracted power) while sbam charges from the grid. Each charge is sized to what is left under the limit, measured on the Fronius meter, and re-checked every 30 s while charging. 0 disables it. Not supported with scheduler_mode: optimize yet: optimize mode refuses to start when it is above 0. See Grid import limit. --grid_import_limit GRID_IMPORT_LIMIT grid_import_limit 0
grid_charge_priority Who gets the power first under grid_import_limit. battery: sbam claims the charge power it needs and backs off only if the site import goes over the limit (a load that does not throttle). Loads that throttle to the meter, such as EV chargers in dynamic mode, yield. loads: sbam only uses the power other loads leave free. --grid_charge_priority GRID_CHARGE_PRIORITY grid_charge_priority battery
grid_import_margin Watts kept free under grid_import_limit. Must be lower than the limit. --grid_import_margin GRID_IMPORT_MARGIN grid_import_margin 200
pw_base_load House load in watts the battery has to cover until PV takes over. Used by reserve_horizon: until_solar. 0 uses pw_consumption / 24. --pw_base_load PW_BASE_LOAD pw_base_load 0

Grid import limit

Battery charging from the grid shares the contracted power with every other load in the house (an EV charger, a heat pump, an oven). sbam does not need to know what those loads are: the Fronius smart meter reports the grid import and the battery power, so the load of everything else is P_Grid + P_Akku.

With grid_import_limit set, sbam:

  • with grid_charge_priority: battery (default), starts each grid charge at the rate the decision asks for (never above the window's max_charge). 10 s later it reads the meter: if the site import is over the limit because a load did not throttle, it backs off by the excess plus the margin. While the import stays under limit − margin, it grows back to the requested rate;
  • with grid_charge_priority: loads, sizes each grid charge to at most grid_import_limit − grid_import_margin − (P_Grid + P_Akku). If a throttling load already takes the whole line, the battery waits;
  • re-reads the meter every 30 s while a grid charge runs and rewrites the charge rate when it moves by 5 points or more (to 0 % it writes the hold when hold_battery is on, otherwise the defaults);
  • does not charge from the grid when the meter cannot be read, since it cannot know how much power is free;
  • caps a manual MQTT force_charge to the power free under the limit when it is sent (and rejects it when the meter cannot be read). The rate is not re-checked while it runs. The full-charge override (ignore_max_charge: true) is not capped;
  • publishes reserve_target_wh, reserve_deficit_wh, grid_charge_allowance_w and reserve_at_risk (MQTT). reserve_at_risk turns on when the reserve deficit cannot be charged before the window ends at the power free now, so an automation can pause a load if you want.

Use battery when the large load throttles itself (a dynamic EV charger). Both controllers aim at the same line, and with loads the one that yields first gets nothing, so the battery would wait all night behind an EV that starts first. With battery, a load that does not throttle can push the import over the limit for up to 10 s before sbam backs off. A typical setup charges the reserve first and keeps it with hold_battery:

grid_import_limit: 3200   # W, contracted power in the cheap period
windows:
  - name: valle
    start: "00:00"
    end: "08:00"
    max_charge: 2500
    hold_battery: true
    reserve_horizon: until_solar

Reserve until solar

pw_batt_reserve is a fixed amount of energy measured from 0 %, and it says nothing about how long the battery must last after the window ends. On a sunny day the daily forecast can be large enough that sbam skips charging, yet the hours between the end of the cheap window and the moment PV covers the house still come from the grid at the expensive rate.

With reserve_horizon: until_solar on a window, every tick in that window computes the reserve as:

reserve = capacity × batt_min_soc / 100
        + Σ max(pw_base_load − PV forecast, 0) × 0.5 h

The sum runs over Solcast's 30-minute periods, from the window end until the first period whose forecast (summed across sites) reaches pw_base_load. The result is never lower than pw_batt_reserve and never higher than the battery capacity. Reserve charging still only happens inside the reserve window (batt_reserve_start_hr / batt_reserve_end_hr). When no forecast is available, pw_batt_reserve is used.

batt_min_soc: 25         # the inverter keeps 25 %
pw_base_load: 600        # W, typical morning load
pw_batt_reserve: 1800    # lower bound
windows:
  - name: valle
    start: "00:00"
    end: "08:00"
    max_charge: 2500
    hold_battery: true
    reserve_horizon: until_solar

Power and Thresholds

Option Description CLI flag Env var HA add-on key Default
pw_consumption Daily electrical consumption in watt-hours. --pw_consumption PW_CONSUMPTION pw_consumption 11000
pw_lwt Hysteresis lower threshold offset in watt-hours to stop charging. --pw_lwt PW_LWT pw_lwt 0
pw_upt Hysteresis upper threshold offset in watt-hours to start charging. --pw_upt PW_UPT pw_upt 0

pw_consumption in optimize mode

With scheduler_mode: optimize, pw_consumption / 24 is the static fallback for every hour of day with fewer than 3 days of consumption history. It must be greater than 0 in that mode, otherwise startup fails.

Scheduling

crontab + windows: cron drives ticks, but each tick uses the window parameters from the windows: list. This is a transitional mode: cron cadence, multi-window decisions.

Option Description CLI flag Env var HA add-on key Default
scheduler_mode Scheduling mode. crontab — the legacy cron engine. Uses the global crontab field and the top-level start_hr/end_hr single window. Fully backward-compatible with existing configs. windows — the new internal ticker. No cron needed. Ticks fire at per-window intervals (tick_minutes), window transitions are detected at exact boundary times, and a tick fires immediately on startup. This is the recommended mode.. optimize — hourly cost-optimized dispatch on spot prices; see Cost Optimizer and Cost-optimized Dispatch. --scheduler_mode SCHEDULER_MODE scheduler_mode crontab
crontab Cron expression for recurring execution. Deprecated use scheduler_mode: windows instead. --crontab CRONTAB crontab 0 0 0 0 0 (CLI) / 00 00-05 * * * (HA)

crontab deprecation

crontab is deprecated and will be removed in v3.0.0. Migrate to scheduler_mode: windows before then.

crontab vs. windows

  • if scheduler_mode: windows is used, the crontab field is ignored.
  • If scheduler_mode: crontab and windows is empty, the legacy single window (start_hr, end_hr, max_charge) is used.
  • If scheduler_mode: crontab and windows is non-empty, the windows list is used for decisions, but ticks are still driven by the cron schedule.
  • If scheduler_mode: optimize is used, crontab, windows, start_hr/end_hr/max_charge and the reserve window are ignored. A Warn is logged when crontab is set.

HA add-on crontab default

The HA add-on default is 00 00-05 * * * (runs every minute from midnight to 5 AM). The CLI binary default is 0 0 0 0 0 (crontab disabled).

Forecast horizon modes

Mode Behavior
default Current behavior: today before 12:00, tomorrow from 12:00 onward.
next_solar_day Same as default. Targets the upcoming solar day.
remaining_today Only forecast intervals from now through end of local day.
today Full local calendar day.
tomorrow Full next local calendar day.
off Skip forecast retrieval entirely. Only reserve charging is active (no Solcast API calls).

Consumption horizon modes

Mode Behavior
full_day Use pw_consumption as-is.
remaining_today Scale pw_consumption proportionally to the fraction of the local day remaining.
to_next_window Scale pw_consumption by the time from now until the next charge window starts (pw_consumption × hours / 24). The span may cross midnight, and may exceed 24 h for weekday-gapped windows — the result is the expected consumption until the next charge opportunity. Falls back to remaining_today when no next window can be resolved.

How to_next_window picks the next window

The "next window" is resolved as the window whose start is soonest after now, scanned across all configured windows and honouring each window's weekday filter. It is not the next entry in the windows: list, so:

  • Config order does not matter. Windows may be listed in any order; the nearest upcoming start always wins.
  • A later-same-day window is preferred over tomorrow. With, say, a morning and an afternoon window, sitting inside the morning window sizes consumption only to the afternoon start — not to tomorrow.
  • Weekday-gapped coverage lengthens the span. After a window whose next occurrence is days away (e.g. a sat-only or wed-only free-power window), the span — and therefore the sized consumption — can be several times pw_consumption. This is intended: the battery must carry the load until the next chance to charge. It is bounded in practice by battery capacity, so the effect is simply "charge toward full."
  • DST: window times are local wall-clock times and days advance by calendar day, so the next window start stays at its local time across a daylight-saving change. The span is measured in real hours, so on the night of the change it is one hour longer or shorter.

Cost Optimizer

These keys are used by sbam schedule with scheduler_mode: optimize and by sbam optimize. They are ignored in the other modes, so existing configurations stay valid. See Cost-optimized Dispatch for how the optimizer works and the dry-run-first workflow.

In config.yaml and the add-on these options are grouped under one optimizer: map:

scheduler_mode: optimize
optimizer:
  price_entity: sensor.nordpool_kwh_dk2_dkk_3_10_025
  consumption_entity: sensor.solarnet_power_load_consumed
  dry_run: true

The CLI flags keep their flat names (--opt_price_entity, --ha_url, …). Environment variables are OPTIMIZER_<NAME> (for example OPTIMIZER_PRICE_ENTITY); for the Home Assistant access HA_URL and HA_TOKEN are the documented names. The flat keys of the first dev builds (opt_* in config.yaml, OPT_* in the environment) are still read for this release when the optimizer: key is not set, with a deprecation warning at startup. In the add-on, options saved under the old flat names are not carried over: re-enter them under optimizer after the update (dry run is the default until you do).

All CLI flags are long-only. Every problem found at startup is reported in one message (invalid configuration for scheduler_mode=optimize (N problems)) and the process exits with code 1. The values are validated even in dry run.

Home Assistant API

Option Description CLI flag Env var HA add-on key Default
optimizer.ha_url Home Assistant base URL, e.g. http://homeassistant.local:8123. Scheme http or https; no user info, query or fragment. /api is appended if missing. A Warn is logged for plain http to a non-private host. --ha_url HA_URL optimizer.ha_url (optional, hidden) —
optimizer.ha_token Home Assistant long-lived access token. Secret: printed as *** in the startup dump. Required when optimizer.ha_url is set. Prefer the env var over config.yaml and never pass it as a flag in shell history. --ha_token HA_TOKEN optimizer.ha_token (optional, hidden, password) —

How sbam reaches Home Assistant:

Condition Access used
optimizer.ha_url is set optimizer.ha_url with optimizer.ha_token. This also wins inside the add-on.
optimizer.ha_url is empty and the Supervisor token is present (add-on) The Supervisor API proxy with the add-on's own token. Nothing to configure.
Neither Startup error: home assistant access: no Supervisor token found and optimizer.ha_url/optimizer.ha_token are not set.

The startup log line optimize mode active shows ha_access=supervisor or ha_access=url. The Supervisor token is never logged.

To create a long-lived token for Docker or the CLI: in Home Assistant open your Profile → Security → Long-lived access tokens → Create token. A dedicated non-admin user is recommended. sbam only reads from Home Assistant (/api/states/ and /api/history/period/).

Optimizer keys

Option Description CLI flag Env var HA add-on key Default Valid range
optimizer.price_entity Nordpool price sensor (prices incl. VAT), e.g. sensor.nordpool_kwh_dk2_dkk_3_10_025. Required in optimize mode. --opt_price_entity OPTIMIZER_PRICE_ENTITY optimizer.price_entity — sensor.<object_id> (^sensor\.[a-z0-9_]+$)
optimizer.consumption_entity Household load power sensor (W or kW), e.g. sensor.solarnet_power_load_consumed. Required in optimize mode. --opt_consumption_entity OPTIMIZER_CONSUMPTION_ENTITY optimizer.consumption_entity — sensor.<object_id>
optimizer.ev_entity Optional EV charger power sensor (W or kW). Its energy is subtracted from the household load, and it drives the EV guard. --opt_ev_entity OPTIMIZER_EV_ENTITY optimizer.ev_entity — (EV skipped) empty or sensor.<object_id>
optimizer.ev_guard_w EV power in W above which sbam holds the battery instead of letting it discharge into the car in self_consume hours. Needs optimizer.ev_entity. 0 disables it. See EV guard. --opt_ev_guard_w OPTIMIZER_EV_GUARD_W optimizer.ev_guard_w 1000 0–50000
optimizer.history_days Days of consumption history used for the hourly profile. Keep the HA recorder's purge_keep_days at least this high. --opt_history_days OPTIMIZER_HISTORY_DAYS optimizer.history_days 10 1–30
optimizer.battery_efficiency Battery round-trip efficiency η. sbam splits the loss evenly: √η on charging and √η on discharging. --opt_battery_efficiency OPTIMIZER_BATTERY_EFFICIENCY optimizer.battery_efficiency 0.83 > 0 and ≤ 1
optimizer.max_charge_rate_w Maximum battery charge rate in W, measured at the battery (the power stored, after conversion losses), like the inverter's own charge setpoint. Also capped by the inverter's WChaMax. --opt_max_charge_rate_w OPTIMIZER_MAX_CHARGE_RATE_W optimizer.max_charge_rate_w 4500 > 0 and ≤ 30000
optimizer.max_discharge_rate_w Maximum battery discharge rate in W, measured at the battery (the power taken out of it). sbam writes it to the inverter as the AC-side setpoint × √optimizer.battery_efficiency, because the Gen24 discharge setpoint is AC-side (details). Also capped by the inverter's WChaMax. --opt_max_discharge_rate_w OPTIMIZER_MAX_DISCHARGE_RATE_W optimizer.max_discharge_rate_w 4500 > 0 and ≤ 30000
optimizer.min_soc_pct Minimum battery SoC in percent that the plan never goes below. Values below 5 log a Warn. --opt_min_soc_pct OPTIMIZER_MIN_SOC_PCT optimizer.min_soc_pct 7 ≥ 0 and < 100
optimizer.vat_rate VAT rate as a fraction (0.25 = 25 %). Used to derive the sell price. --opt_vat_rate OPTIMIZER_VAT_RATE optimizer.vat_rate 0.25 0–1 (a value like 25 is rejected with a hint)
optimizer.sell_margin Supplier's sell margin in currency/kWh incl. VAT, subtracted from the ex-VAT spot price. --opt_sell_margin OPTIMIZER_SELL_MARGIN optimizer.sell_margin 0 -5–10
optimizer.min_gain Minimum saving in currency per hour before a charge or discharge replaces the inverter's normal self-consumption; hold and standby need a tenth of it. Smaller gains stay self_consume. 0 disables the threshold. See minimum gain and wear cost. --opt_min_gain OPTIMIZER_MIN_GAIN optimizer.min_gain 0.5 0–10
optimizer.wear_cost Battery wear cost in currency per kWh a forced charge or discharge moves beyond self-consumption, added to optimizer.min_gain. Example: 0.15. 0 disables it. --opt_wear_cost OPTIMIZER_WEAR_COST optimizer.wear_cost 0 0–5
optimizer.purchase_surcharge 24 hourly surcharges (grid tariff, taxes, fees) in currency/kWh incl. VAT, added to the spot price. First value = 00:00–01:00. See the format below. --opt_purchase_surcharge OPTIMIZER_PURCHASE_SURCHARGE optimizer.purchase_surcharge 24 × 0 exactly 24 numbers, each -5–10
optimizer.dry_run Compute and publish the plan without writing to the inverter. Set to false to go live. Must be true or false; a malformed value is an error and sbam stays in dry run. --opt_dry_run OPTIMIZER_DRY_RUN optimizer.dry_run true true / false

Dry run is the default everywhere

optimizer.dry_run defaults to true on the CLI, in Docker and in the add-on. Work through Before going live before setting it to false.

Surcharge format (optimizer.purchase_surcharge)

  • Exactly 24 numbers, one per hour of the day, starting with 00:00–01:00.
  • Use . as the decimal separator. A decimal comma (0,52) splits into two values and fails the count check.
  • Negative values (for example a rebate) are allowed. Empty items (0.5,,0.5) and non-numbers are errors.
  • CLI flag, env var and add-on: one comma-separated string, e.g. "0.52,0.52,0.52,0.52,0.52,0.52,0.78,0.78,0.78,0.78,0.78,0.78,0.78,0.78,0.78,0.78,0.78,2.04,2.04,2.04,2.04,0.78,0.78,0.78".
  • config.yaml: the same string, or a YAML list of 24 numbers.
  • Empty or unset means 24 × 0.

Error examples:

optimizer.purchase_surcharge: expected exactly 24 comma-separated numbers (hour 00..23), got 23; use '.' as decimal separator
optimizer.purchase_surcharge: item 7 ("0,78x") is not a number

Prices. For every hour: buy = spot incl. VAT + surcharge[hour of day] and sell = spot incl. VAT / (1 + optimizer.vat_rate) − optimizer.sell_margin. Example: spot 2.00, surcharge 2.04, VAT 0.25, margin 0.05 gives buy = 4.04 and sell = 1.55.

Efficiency and terminal value. Charging ΔE into the battery costs ΔE / η, so grid-charging only pays when a later price beats the current price ÷ η. Energy left at the end of the horizon is valued at η × mean(buy) per kWh, so a short horizon does not empty the battery.

Other keys in optimize mode. fronius_ip, url and apikey are required as in the other modes. The PV forecast is always read through the forecast cache (cache_file_prefix, cache_time), whatever cache_forecast says; a cached forecast older than max(cache_time, 24 h) is treated as missing.

Forecast Caching

Option Description CLI flag Env var HA add-on key Default
cache_forecast Enable forecast caching to reduce API calls. --cache_forecast CACHE_FORECAST cache_forecast false
cache_time Forecast cache TTL in seconds. --cache_time CACHE_TIME cache_time 7200
cache_file_prefix Forecast cache file name prefix. --cache_file_prefix CACHE_FILE_PREFIX cache_file_prefix cached_forecast

MQTT

See the MQTT Guide for detailed setup, topic mapping, payload schemas, and command examples.

Option Description CLI flag Env var HA add-on key Default
mqtt_enabled Enable MQTT publishing and command subscription. --mqtt_enabled MQTT_ENABLED mqtt_enabled false
mqtt_broker MQTT broker URL (e.g., tcp://broker:1883). In HA add-on, auto-fills from Home Assistant service data if empty. --mqtt_broker MQTT_BROKER mqtt_broker —
mqtt_client_id MQTT client identifier. Auto-generated if empty. --mqtt_client_id MQTT_CLIENT_ID mqtt_client_id random
mqtt_username MQTT username. In HA add-on, auto-fills from Home Assistant service data if empty. --mqtt_username MQTT_USERNAME mqtt_username —
mqtt_password MQTT password. In HA add-on, auto-fills from Home Assistant service data if empty. --mqtt_password MQTT_PASSWORD mqtt_password —
mqtt_topic_prefix Prefix for sbam state, availability, and command topics. --mqtt_topic_prefix MQTT_TOPIC_PREFIX mqtt_topic_prefix sbam
mqtt_ha_discovery Enable Home Assistant MQTT discovery (publishes retained discovery configs). --mqtt_ha_discovery MQTT_HA_DISCOVERY mqtt_ha_discovery true
mqtt_ha_discovery_prefix Home Assistant discovery root topic prefix. --mqtt_ha_discovery_prefix MQTT_HA_DISCOVERY_PREFIX mqtt_ha_discovery_prefix homeassistant
mqtt_tls_ca_file MQTT TLS CA certificate file path. CLI/standalone only. --mqtt_tls_ca_file MQTT_TLS_CA_FILE — —
mqtt_tls_client_cert MQTT TLS client certificate file path. CLI/standalone only. --mqtt_tls_client_cert MQTT_TLS_CLIENT_CERT — —
mqtt_tls_client_cert_key MQTT TLS client key file path. CLI/standalone only. --mqtt_tls_client_cert_key MQTT_TLS_CLIENT_CERT_KEY — —
mqtt_tls_insecure_skip Skip MQTT TLS certificate verification (insecure). CLI/standalone only. --mqtt_tls_insecure_skip MQTT_TLS_INSECURE_SKIP — false

HA MQTT auto-fill

When running as a Home Assistant add-on, the MQTT broker, username, and password are automatically filled from the Home Assistant service data if left empty. This allows sbam to connect to the same broker as Home Assistant without requiring manual configuration.

Operational

Option Description CLI flag Env var HA add-on key Default
defaults At end of crontab cycle, reconfigure Fronius inverter to defaults. --defaults DEFAULTS defaults true
reset At add-on startup, reconfigure Fronius inverter to defaults. — — reset false
debug Increase log level to debug. — DEBUG debug false
log_type Logger output mode: console (human-friendly) or json (machine-readable). — LOG_TYPE log_type console